Get complete information related to latest Laboratory Analyzer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Laboratory Analyzer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Laboratory Analyzer Tenders.
Tender For custom bid for services - agency for electrical testing jobs at various sub-stations and associated locations of iocl guwahati refinery, tender no-9010c25b16-a. scope of work for service line#10 electrical troubleshooting, scheme modifications & reliability improvement jobs manpower to be deputed at site as per clause 1.3 and following jobs/ activities shall be required to be carried out as per requirement and instruction of site engineer/ engineer-in- charge of iocl. the activities mentioned below gives a tentative idea of the jobs to be carried out. however, the jobs that are not mentioned here but which come under the scope of testing related jobs shall also be included as per the instructions/ directions of site engineer/ engineer-in-charge as part of the job with no additional financial implication on iocl. all equipment, instruments, wires, connectors etc. required for carrying out the job shall be in the scope of the party. b. scope of work for service line#20 to & fro transportation charges of additional electrical equipment/ instrument as per site requirement to & fro transportation charges of additional equipment/ instrument (auto/ manual transformer winding resistance meter/ circuit breaker analyzer kit for breaker close, open, close-open timing/ secondary current injection testing kit (make: omicron, freja, megger, scope)/ hv ac kit / hv dc kit suitable for 132kv system) required at site as decided by eic including all charges, arrangements, requirements to be done to make the instrument available at site as per requirement per equipment/ instrument per trip. if the equipment gets defective during the use at site or could not be used at site due to unsuitable personnel or unsuitable equipment/ instrument due to any reason, then the to and fro transportation charge shall not be paid. c. scope of service for service line#30 hire charges per week (07 working days) for auto/ manual transformer winding resistance meter as per site requirement hire charges per week (07 days) for providing and utilizing the auto/ manual transformer winding resistance meter of reputed make required at site for site testing related activities with the equipment/ instrument. d. scope of service for service line#40 - hire charges per week (07 working days) for circuit breaker analyzer kit for breaker close, open, close-open timing as per site requirement hire charges per week (07 days) for providing and utilizing the circuit breaker analyzer kit for breaker close, open, close-open timing of reputed make required at site for site testing related activities with the equipment/ instrument. e. scope of service for service line#50 hire charges per week (07 working days) for secondary current injection testing kit upto 150a (make: omicron, freja) as per site requirement hire charges per week (07 days) for providing and utilizing the secondary current injection testing kit upto 150a (make: omicron, freja, megger, scope) of reputed make at site for site testing activities with the equipment/ instrument. f. scope of service for service line#60 hire charges per week (07 working days) for hv ac kit suitable for 132kv system as per site requirement hire charges per week (07 days) for providing and utilizing the hv ac kit of reputed make at site for site testing activities with the equipment/ instrument. g.scope of service for service line#60 hire charges per week (07 working days) for hv dc kit suitable for 132kv system as per site requirement hire charges per week (07 days) for providing and utilizing the hv dc kit upto 132kv of reputed make at site for site testing activities with the equipment/ instrument..
Tender For supply of antacid chewable containing dried aluminium hydroxide ip 250 mg mag hydroxide nf 250 mg methyl polysiloxane 50mg tab , compression elastic bandage for dvt large , polypropelene blue monofilament 70-75 cms size 2 by 0 3 by 8 circle reverse cutting 12 mm , polypropelene blue monofilament 70-75 cms size 3 by 0 3 by 8 circle reverse cutting 12 mm , sodium chloride 3percentage solution 100 ml , typhoid vi conjugate vaccine 0.5 ml single dose for pediatric use , syp ranitidine , pvc reinforced metal intubation stylet for endo tracheal intubation size 14 fr , haemaccel 500 ml bottle containing colloidal infusion solution of polygeline with electrolytes , water seal chest drainage system with thoracic trochar catheter , syp paracetamol 250mg per 5ml , chlorhexidine gauze dressing , activated charcoal powder pkt of 50 gm for oral use , i gel size 2 , omega 3 fatty acid capsule , magnesium sulphate paste 50 gm bottle , syp multivitamin paediatric , povidone iodine ointmet 5 percentage , i gel size 3 , i gel size 4 , syp levosalbutamol 1mg per 5ml plus guaiphenesin 30mg per 5ml ambroxol hcl 50mg per 5ml for adult use 100 ml bottle , syp levosalbutamol 0 point 5mg per 5ml plus guaiphenesin 50mg per 5ml ambroxol hcl 15 mg per 5ml for pediatric use , silver suphadiazine 0 point 5 percentage and chlorhexidine gluconate 0 point 2 percentage cream tube of 20 gm , modafinil 200 mg tab , philadelphia cervical collar orthosis size l , philadelphia cervical collar orthosis size xl , indacaterol maleate and glycopyrronium bromide inahalationalpowder hard capsules 110 and 50 mcg , fluromethalone eye drops , quality control kit n h l kit for erba h 360 hematology analyzer , pm kit for chem 7 semi auto biochemistry analyzer , flunarizine 10 mg tab , silodosin 8 mg tab , fluticasone propionate 50 mcg bp nasal spray , tropicamaide eye solution 1percentage bott of 5 ml , phenylephrine hydrochloride plus naphazoline hydrochloride eye drops , lignocaine hcl 2percent with adrenaline 30 ml inj , doxylamine succinate 10mg usp plus pyridoxine hydrochloride 10mg ip tab , syp calcium and vit d3 //bid details 2 / 57
Tender For providing of selection of laboratories for testing of products/material - fully automated esr analyzer; buyer to use custom filter to input technical specification of the product/material so that service provider may provide price offering accordingly; fully auto..
Tender For corrigendum : fully automatic analyzer - equipments, fully auto analyzer, cmc for 1st year, cmc for 2nd year, cmc for 3rd year, cmc for 4th year, cmc for 5th year
Tender For instruments for shrawani mela year 2025-26, hospital and other health centre. - stainless steel abdominal hysterectomy set, n.s.v set (s.s), g.v set, self abdominal detractor, m.t.p set., vaccine carrier (small size), x-ray digitalisation with high-end cr system (with installation & 1 yers. warrenty) console software with mulitmodality work station the cr system should have advances workstation provided with 17" high resolution monitor, keyboard & ouse, with the fol., digital ultrasound machine colour dopler (high resolution ) with 4 probe, semi auto analyzer, fully automated bio-chemistry analyzertechnical specificationsthroughput-150t/hr (constant with both mono and double reagent)system function-random access/stat/batchtest method-end point, fix time, kinetic, (single/double reagents chemistry, mono/ bio-chromatic measurements)calculation methods-1 point linear, 2 point linear, exponential, logit log3p, logit log 4 p, logit log 5p, spline, line graph, k factorblank-reagent blank, sample blank, pre sample blank, pre reagent blanksample tray-40 position, sample volume :2-30 ui, 0.1 ul increment, micro cup, & test tube can be used for samplereagent tray-80 position, reagent volume: 20-300 ul, 1 ul incrementmixing system-teflon coated mixersample probe-1 needle with liquid detector, shock sensoroptics-halogen-tungsten lamp, absorbance range: 0-4.0 abs resolution: 0.0001 abs.diffraction photometry with wave length: 340, 405, 450, 505, 546, 578, 630, 700nm & 4 more optionswash station-12 step washing, 4 needle wash station, 1 dry pad, external needle cleaningcalibration-linear and non-linearqc-multi-level qc setup with levy-jennings graph and westgrads multi rules with mean sd, and cvwater consumption-not more than 6l/hrtemperature-reagent: 2-14 c (24 hr refrigeration), reaction cuvette: 37c 0.1 humidity- 80%system interface-usbpower requirement-ac 220v 10%, 50/60 hzdimensions-750 mm*560mm*530mm, hotair oven, binocular microscope (olampus), centri fuge machin (good quality), micropipette (0-50 microliter), micropipette (0-500 microliter), micropipette (0-1000 microliter), microtips (0-50 microliter), microtips (0-1000 microliter), bed side screen with cloth 1"round pipe with wheel, sponge holding (all size), artery forceps 6" curved, artery forceps 6" straight., artery forceps 8" curved, artery forceps 8" straight., artery forceps 4" straight., alliys tissue forcep (all size curved straight), mosquito forcep (all size curved straight), scissor 6 " curved (all size), scissor 6 " straight (all size), scissor mosquito straight. (all size curved, straight), diatheromy (machine), laparoscopic instrument full set (best quality), needle holder 8 "curved, needle holder 8 " straight, needle holder 6 "curved, needle holder 6 " straight, needle holder 4 "curved, needle holder 4 " straight, doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside, elisa reader with washer mechine with printer & ups., fully automated chemiluminescence analyzer(clia) 1. system should be fully automated walk -away with continuous loading facility.2. analyzer should have able to perform thyroid, bone, cardiac, fertility, diabetes and anemia profile test.3. working principle of system should be micron super paramagnetic particles platform with alp labeled reagents and amppd substrate.4. must have 3 phase magnetic separation with precisely controlled temperature.5. analyzer should have photon counting detection mode with photomultiplier photo counter with led reference module.6. the analyzer must have vortex non-touch mixing which can reduce carryover., 7. throughput of the system should be more than 180 tests in a hour.8. system should have 15 reagents onboard with onboard 2 -8 nonstop refrigeration facility 9. system should have at least 50 sample positions and continuous loading facility.10. system should have continuous reagents loading, real time mixing for magnetic particles.11. sample probe a